Gaskets
All discs are supplied with "factory-installed" integrated flange gaskets. The standard material is EPDM and can be used from -40 °C to +120 °C. As an alternative the following standard materials are available:
White Silicone - 50 °C to +200 °C
Klinger - 100 °C to +400 °C
Ceramic -100°C to +900 °C
Other materials can be supplied on request.
Insulation
Insulation consists of a fire-proof mineral wool according to DIN 1259. The insulation is directly mounted to the "vent- side" of the explosion vent and is protected by a light-weight aluminium cover with a water-tight seal. It is secured to the disc to prevent it from flying away during venting. BRILEX insulation does not have any affect on the venting relief capability or efficiency. This has been proved by recognized institutes in many dynamic explosion tests. Optional insulation thickness can be supplied to meet the customer's specifications.
Mounting Frames
The necessary outlet flange for types GE / KE can also be supplied. The following material is available: Zinc plated carbon steel or stainless steel.
Burst Sensor
To monitor an installation a burst sensor type SE can be installed. The sensor signals the opening of the bursting disc so that equipment such as fans or rotary valves can be switched off. SE sensors are installed separately and just above the explosion vent. This enables SE sensors to be easily adapted to existing installations.They are also suitable for the food industry.
back to overview